If the wall
slopes out, the base plate will need to move closer to the
wall in order to align with the upper pivot in the pivot
wall block. If the wall slopes in, the base plate must move
away from the wall.
To locate the wall block vertical position, hold the
entire door glass/pivot channels/wall block assembly in
place in the closed position on the pivot base plate. With
a 1/8" spacer
between the upper channel and the top socket, mark the top
of the wall block mount on the wall.
Transfer the wall block mount hole positions to the
wall.
To determine whether there is a stud backing, drill
a 3/32" diameter
hole in one screw location. If there is a stud backing,
3/32" diameter
holes are sufficient. If there is no stud backing, drill
7/32" diameter
holes and use the screw anchors supplied.
Using three #8 x 2 1/2" long screws, fasten the wall block
mount to the wall on the glass center-line with the top
level.
Depending on
the composition of the wall and backing, the installer must
determine whether the 2 1/2" screws will secure to a stud
or require a screw anchor.
With the pivot wall block in place on the upper channel,
the door assembly can be slid in place under the wall block
mount and secured with the flat head screws provided. The
wall block must be pushed tight to the wall.